Explosion Proof Chain Hoist
Explosion proof mark Exd Il BT4 Gb/ExtD A21 IP65 T130 ℃
Explosion proof mark Exd II CT4 Gb/ExtD A21 IP65 T130 ℃
Products Description
The shell, chain, and electrical components of the EMET-EPB series Explosion-proof Chain Hoist are made of beryllium bronze and aluminum bronze. They have undergone special explosion-proof treatment, effectively preventing safety hazards such as small sparks. Therefore, it is safe to use in environments with dense dust particles or flammable and explosive gases. Both hooked and pulley models are available, and a wireless remote controller is optional.
Main Features
1. Aluminum bronze shell: crafted from specialized aluminum bronze material, with explosion-proof surface treatment;
2. Chain: Nickel hardened chain undergoes special MODE treatment, which does not affect the performance of the original chain but has anti-corrosion effect;
3. The lifting motor and operating motor of the explosion-proof chain hoist are both explosion-proof with a level of ExdIICT4, a motor protection level of IP55, and an insulation level of F;
4. Overload protector: prevents automatic power cut-off caused by overheating of the overloaded motor;
5. Fire limiter: The fire limiter is explosion-proof, with a larger volume and heavier weight compared to ordinary models. It is marked with an EX certification for explosion-proofing.
6. Electric pulley: equipped with stainless steel welding rods, rustproof and wear-resistant, effectively preventing sparks generated due to friction.





Technical Index
Working environment:
1. Altitude: ≤ 1000m
2. Surrounding air temperature:- 20℃ ~ 40℃
3. Grid fluctuation: ± 10%
4. Relative humidity: ≤ 85%, suitable for situations where water dripping can be prevented
Class I: Electrical equipment underground in coal mines;
Class II: All electrical equipment used in explosive gas environments other than coal mines and underground mines can be divided into IIA, IIB, and IIC categories. They are suitable for use in Class IIA environments. The IIC symbol is also applicable to environments of IIA and IIB categories.
Maximum surface temperature: The highest temperature reached by any component of electrical equipment that may cause ignition in the surrounding explosive environment when operating under the most unfavorable conditions within the specified range.
| EMET-EPB Series Technical Parameters | ||||||
|
Model No. |
Rated Load Capacity |
Numbers of Chains |
Diameter of chains(mm) |
Lifting Speed(m/min) |
Motor Power(KW) |
Explosion proof Item |
|
EMET-EPB 1-01 |
1.0T |
1 |
∅7.1 |
6.8 |
1.5 |
IIB |
|
EMET-EPB 2-01 |
2.0T |
1 |
∅10.0 |
6.6 |
3.0 |
IIB |
|
EMET-EPB 2-02 |
2.0T |
2 |
∅7.1 |
3.4 |
1.5 |
IIB |
|
EMET-EPB 3-01 |
3.0T |
1 |
∅11.2 |
5.6 |
3.0 |
IIB |
|
EMET-EPB 3-02 |
3.0T |
2 |
∅10.0 |
3.3 |
3.0 |
IIB |
|
EMET-EPB 3-03 |
3.0T |
3 |
∅7.1 |
2.2 |
1.5 |
IIB |
|
EMET-EPB 5-02 |
5.0T |
2 |
∅11.2 |
2.8 |
3.0 |
IIB |
|
EMET-EPB 7.5-03 |
7.5T |
3 |
∅11.2 |
1.8 |
3.0 |
IIB |
|
EMET-EPB 7.5-03 |
7.5T |
3 |
∅11.2 |
1.8 |
3.0 |
IIC |

Product Size
Unit(mm)
|
Type |
H |
A |
B |
D |
E |
I |
J |
K |
L |
N |
P |
R |
T |
Chain |
I-BEAM |
|
EMET-EPB 1-01 |
650 |
700 |
405 |
380 |
235 |
φ31 |
111 |
φ40 |
31 |
24 |
206 |
300 |
360 |
φ7.1 |
80-160 |
|
EMET-EPB 2-01 |
740 |
700 |
405 |
380 |
235 |
φ36 |
127 |
φ49 |
35 |
30 |
237 |
302 |
362 |
φ7.1 |
82-178 |
|
EMET-EPB 2-02 |
770 |
825 |
460 |
460 |
250 |
φ36 |
127 |
φ49 |
35 |
30 |
237 |
302 |
362 |
φ10.0 |
82-178 |
|
EMET-EPB 3-01 |
1000 |
700 |
460 |
460 |
295 |
φ43 |
140 |
φ59 |
42 |
35 |
265 |
305 |
365 |
φ10.0 |
110-178 |
|
EMET-EPB 3-02 |
940 |
825 |
460 |
460 |
290 |
φ43 |
140 |
φ59 |
42 |
35 |
265 |
305 |
365 |
φ11.2 |
100-180 |
|
EMET-EPB 3-03 |
840 |
825 |
460 |
460 |
250 |
φ43 |
140 |
φ59 |
42 |
35 |
265 |
305 |
365 |
φ11.2 |
100-180 |
|
EMET-EPB 5-02 |
1015 |
825 |
460 |
460 |
290 |
φ54 |
156 |
φ60 |
45 |
43 |
296 |
312 |
372 |
φ11.2 |
110-180 |
Major technical barriers to explosion-proof design
Motor Casing
The motor casing of Explosion-proof Chain Hoist needs to adopt an explosion-proof structure, which ensures that internal electric sparks do not ignite external explosive gases through thickened steel plates and precision welding processes.
Conductive Components
Conductive components of Explosion-proof Chain Hoist need to undergo electrostatic discharge treatment to avoid the accumulation of charges and the generation of electric sparks.
Brakes and Limiters
Key components such as brakes and limiters need to use non sparking materials, such as copper based alloys, instead of traditional steel, to eliminate the risk of friction sparks from the source.
Why Choose EMET's Explosion-proof Chain Hoist
Material research and development capability:
Explosion-proof chain hoist requires the use of special alloys and composite materials, and EMET has the ability to analyze material composition and control heat treatment processes. For example, the chain link needs to be treated with carburizing and quenching to improve surface hardness while maintaining toughness, preventing safety accidents caused by fracture.
Precision manufacturing process:
From gear meshing accuracy to housing sealing, every detail is related to explosion-proof performance. EMET uses CNC machining centers and laser welding technology to control part errors within 0.01 millimeters, ensuring stable operation of the equipment in extreme environments.
Safety certification system:
Explosion-proof chain hoists should pass explosion-proof level certifications such as Ex d IIB T4, and EMET establishes a full process quality control system covering design, production, and testing. For example, each device needs to undergo 48 hours of continuous load testing and air tightness testing before leaving the factory to ensure that everything is foolproof.
Explosion-proof Chain Hoist In Factory

Hot Tags: explosion proof chain hoist, China explosion proof chain hoist manufacturers, factory, Hydraulic Material Lifting Platform, Jib Cranes
Next
Cleanroom HoistYou Might Also Like